WKT (-C)-T3A – HEAT RESISTANCE CORRUGATED TUBE
Temperature range:
from -25°C to +125°C
Flexibility: pliable
Flammability: flammable
Material: polypropylene mod. (PP mod.)
Colour: black with blue stripe
Application:
Cable protection applications in automotive wiring systems, specifically appropriate for engine wires, industrial equipment, control systems and other electro-technical installations. An insulator with extremely high flexibility and percussive strength, resistant to most chemical compounds, it meets the high standards required to effectively provide protection for wiring systems.
The tubing is available in two versions:
– Standard
– Longitudinally cut version
Characteristics of material:
Flammable (T3A) or self-extinguishing (T3B) heat resistant material, negligible gas and vapour permeability within a wide temperature range, good elasticity and impact resistance, minimal deformability under strain, high resistance to oil, petrol, pressure, and most chemical compounds.
Available diameters
Inside diameter (mm) | Outside diameter (mm) | Coil length (m) |
---|---|---|
4,5 | 7 | 100 |
6,8 | 10 | 50, 100, 200 |
9 | 14 | 50, 100 |
11,4 | 15 | 50, 100 |
13 | 18 | 50, 100 |
16 | 21 | 50, 100 |
18 | 22 | 50, 100 |
21 | 25 | 25, 50 |
23 | 28 | 25, 50 |
26 | 32 | 25, 50 |
29 | 36 | 25, 50 |
Special diameters
Inside diameter (mm) | Outside diameter (mm) | Coil length (m) |
---|---|---|
8,5 | 11,6 | 25, 50, 100 |
10,1 | 12,7 | 25, 50, 100 |
12 | 15,6 | 25, 50, 100 |
12,9 | 15,8 | 25, 50, 100 |
14,5 | 18,3 | 25, 50, 100 |
16,8 | 21 | 25, 50, 100 |
21,8 | 25,5 | 25, 50 |
23,7 | 28 | 25, 50 |
29,3 | 33,9 | 25, 50 |
36,7 | 42 | 25 |
Resistance to selected chemical compounds
Acids | weak | high |
strong | high | |
oxidized | lack | |
hydrofluoric | high | |
Bases | dry halogens | lack |
weak | high | |
strong | high | |
Solvents | alcohols | high |
esters | high | |
ketones | high | |
ethers | medium | |
chlorinated hydrocarbons | medium | |
Oil and diesel materials | benzene | medium |
petrol | medium | |
diesel mixtures | medium | |
mineral oils | medium | |
fatty oils | high |
Places of Applications
Wall installations | admissible |
Sunk installations | not allowed |
Outer wall installations | admissible |
Plaster walls | not allowed |
Combustible surfaces (wood, etc.) | not allowed |
Underground installations | not allowed |
Poured concrete, vibrated concrete | not allowed |
Steamed and vibrated concrete | not allowed |
Electrotechnical equipment, industrial apparatus | recommended |
Control and automatics | recommended |
Food and chemical industry facilities | recommended |
Automotive industry | recommended |
Shipyard industry | recommended |
Aircraft industry | recommended |